Microducts for Indoor Installations

 

 

 

Microducts, Indoor, High Grade or UL Riser, 5/3.5 mm

MPB 302 01+ — MPB 302 08+

Description
Microducts with a sheath made of halogen-free, flame retardant material. The ducts are also available in a UL Riser rated series. The microducts have a solid, low-friction inner surface coating for best installation performance. There is also a single microduct available with an extra protection sheath for mounting directly onto walls with cable clamps. All flame retardant microduct assemblies are halogen-free (HFFR).

 

Technical Information
Design: Tight protected ducts, HFFR High Grade
Type: Indoor installation, IEC 60332-3-24 or UL 1666 OFNR
Capacity: 1-24-way
Dimensions: OD/ID Ø5/3.5 mm
Lengths: 500, 1000, 2000 m

 

Microducts, Indoor, Standard Grade, 5/3.5 mm

MPB 302 09+, MPB 302 51

Description
Microducts with a sheath made of halogen-free, flame retardant material with Standard Grade classification for installations with normal fire requirements. There is also a single microduct available with an extra protection sheath for mounting directly onto walls with cable clamps. All flame retardant microduct assemblies are halogen-free (HFFR).

 

Technical Information
Design: Tight protected ducts, HFFR Standard Grade
Type: Indoor installation, IEC 60332-1
Capacity: 1-24-way
Dimensions: OD/ID Ø5/3.5 mm
Lengths: 500, 1000, 2000 m

Microducts, Indoor, High Grade, 3/2 mm

MPB 302 46+

Description
Exra slim microducts with a sheath made of halogen-free, flame retardant material. The micro­ducts have a solid, low-friction inner surface coating for best installation performance. These ducts are especially suitable when installing in buildings with limited space in risers. All flame retardant microduct assemblies are halogen-free (HFFR).

 

Technical Information
Design:
Tight protected ducts, HFFR High Grade
Type: Indoor installation, IEC 60332-3-24
Capacity: 1-24-way
Dimensions: OD/ID Ø3/2 mm
Lengths: 500, 1000, 2000 m

Microducts, Indoor, Standard Grade, 3/2 mm

MPB30243+

Description
Exra slim microducts with a sheath made of halogen-free, flame retardant material with Standard Grade classification for installations with normal fire requirements. These ducts are especially suitable when installing in buildings with limited space in risers. All flame retardant microduct assemblies are halogen-free (HFFR).

 

Technical Information
Design: Tight protected ducts, HFFR Standard Grade
Type: Indoor installation, IEC 60332-3-24
Capacity: 1-24-way
Dimensions: OD/ID Ø3/2 mm
Lengths: 500, 1000, 2000 m

Microducts, Indoor, 10/8 mm and 12/10 mm

MPB 302 71+, MPB 302 73+

Description
Microducts  with a sheath made of halogen-free, flame retardant material for installations with normal fire requirements. Fiber splicing between indoor and outdoor environments can therefore be eliminated All flame retardant microduct assemblies are halogen-free (HFFR).

 

Technical Information
Design: Tight protected ducts, HFFR Standard Grade
Type: Indoor installation, IEC 60332-1
Capacity: 1-7-way
Dimensions: OD/ID Ø10/8 or 12/10 mm
Lengths: 500, 1000, 2000 m

 

Microducts, Indoor and Outdoor, 5/3.5 mm

MPB 302 52+

Description
The indoor/outdoor tight protected microduct consist of a halogen free, flame retardant inner duct with a removable, UV resistant outer sheat. This design makes it possible to install the duct outdoors on facades. Sections of the duct can aslo be installed indoors by simply removing the outer sheath, exposing the flame retardant inner duct.

The microduct can be mounted onto facades with cable clamps (7mm). The microducts are optimized for best performance in combination with the Hexatronic Stingray air blown fiber.

 

Technical Information
Design: Tight protected ducts, HFFR 
Type: Outdoor installation, Indoor installation, IEC 60332-3-24
Capacity: 1-way
Dimensions: OD/ID Ø5/3.5 mm
Lengths: 500 m

 