MTV2100

De-icing agent for microducts

Application

The agent is normally used in microducts for cables with an inner diameter of 3.5-16 mm.

Caution

Only use the liquid inside microducts. Avoid contact with other surfaces. Use a funnel or pipette or similar to fill the microducts. If the liquid is splashed or spilled on other surfaces, rinse with water, clean and dry all surfaces thoroughly.

Ensure to blow out remaining liquid from the microducts according to instructions. To avoid spill, use a bucket or extension hose for waste liquid.

Non-blocked ducts

If the microduct is not 100% blocked and some air can be forced through the duct, do as following:

  1. Add at least 20 cm of the liquid into the microduct end and if required, force the liquid to flow to the ice blockage by air pressure.
  2. If there are plenty of ice, more liquid needs to be added into the microduct.
  3. Blow out the fluid with the melted ice and ensure that the duct is 100% dry by blowing through cleaning sponges.

Blocked ducts

In general, it is very hard to melt a totally blocked microduct filled with ice. If a totally blocked microduct needs to be cleared the above procedure can be used, except that air pressure cannot be used.

  1. Fill the blocked duct completely
  2. Allow the ice to melt at least 12 hours before trying to blow out the melted ice.
  3. Blow out the fluid with the melted ice and ensure that the duct is 100% dry by blowing through cleaning sponges.

SDS

Access the Safety Data Sheet (SDS).