MTV11002/1 - lubricant for cable installation into microducts, all season
Application
- Clean and dry the tubing by blowing a tight-fitting foam sponge through the microduct with high pressure. If excess water or dirt comes from the microduct, repeat the process. Trapped water can block the airflow.
- Shake the bottle before use.
- Squeeze the recommended amount of lubricant into microduct. Quantity can be measured with a syringe or estimated based on duct fill length (table below).
- Spread lubricant by blowing a foam carrier or sponge through the microduct as many times as necessary to avoid puddling at the front of the duct.
- Allow the duct lubricant to dry out completely by blowing in air for at least 5 minutes.
Tube size OD/ID |
Lubricant per km, duct, volume required |
Microduct fill length |
16/12 mm |
15 ml |
13 cm |
16/10, 14/10, 12/10 mm |
12 ml |
15 cm |
10/8 mm |
10 ml |
20 cm |
10/6, 8/6 mm |
7 ml |
26 cm |
7/5 mm |
6 ml |
30 cm |
7/3.5, 5/3.5 mm |
5 ml |
44 cm |