- Products
- Cables
- Duct Cables
- Slotted Core Ribbon Cable
TOL4011001+A
Slotted Core Ribbon Cable
GAHSL 12-192 fibers G652D S12
- Water blocking filling compound prevents water penetration along the cable
- 12-192 fibers, G652.D
- High packing density of the fibers is provided by the ribbon technique
- Dielectric
- Suitable for installation by blowing, floating or pulling
- Water blocking filling compound prevents water penetration along the cable
- 12-192 fibers, G652.D
- High packing density of the fibers is provided by the ribbon technique
- Dielectric
- Suitable for installation by blowing, floating or pulling
GAHSL is a 4-fiber or 8- fiber ribbon cable mainly for duct installation. There is also a slim variant available (TOL 401 1013). Being completely dielectric it can be installed in environments where there can be electrical interference, for example adjacent to power lines. The versatility of this cable design and the improved splicing properties of the ribbon technology, reduce the cost of installation.
The slotted core ribbon cables are designed with 4- or 8-fiber ribbons to gives high packing density of the fibers.
The glass fiber reinforced strength member and the slotted core design provide superior protection for the fiber ribbons.
- 4- or 8-fiber ribbon: Silica, acrylate
- Filling compoiund: Thixotropic gel
- Central strength member: Glass fiber reinforced plastic
- Slotted core: Polyethylene
- Sheath: Polyethylene, halogen-free
Technical Information
Product Color | Black Sheath |
---|---|
Color Code | S12 |
Temperature, Operation [°C] | –30 to +70 |
Temperature, Storage [°C] | –40 to +70 |
Temperature, Installation [°C] | –15 to +50 |
Water Blocking | Longitudinal water blocking according to IEC 60794-1-2-F5 |
Fiber Type | G652D |
Attenuation @Wavelength [nm] | 1310/1550/1625 |
Average Attenuation [dB/km] | 0.33/0.21/0.23 |
Maximum Attenuation [dB/km] | 0.36/0.23/0.25 |
Conformance | Longitudinal water blocking according to IEC 60794-1-2-F5. Mechanical and environmental tests in accordance with IEC 60794-1. Fiber parameters and tests according to the IEC series 60793-2 and 60793-1. |
Marking | Example of sheath marking, 1 time/meter: “HEXATRONIC A35 yymmddhh TOL4011001/96A GAHSL-U-DFNV 96/C4 G652D S12 xxxxx m" where yymmddhh = year, month, day and hour of manufacture, xxxxx=running meter marking. |
Installation Notes | If duct installation the cable should be installed at a temperature between -15 to +40°C. The cable shall not be stored in direct sunlight. The sun may heat up the cable over the permitted temperature limit. |
Ordering Information | Supplied lengths: 2, 4, 6, 8 or 12 km |